Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2024)

The Cisco Nexus 93180YC-FX3 switch (N9K-C93180YC-FX3, N9K-C93180YC-FX3H) is a 1-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. This switch has the following ports:

  • 48 100M/1/10/25-Gigabit Ethernet SFP28 ports (ports 1-48).

  • 6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49-54)

  • One management port (one 10/100/1000BASE-T port)

  • One console port (RS-232)

  • 1 USB port

This switch includes the following user-replaceable components:

  • Fan modules (four) with the following airflow choices:

    • Port-side exhaust fan module with blue coloring (NXA-FAN-35CFM-PE)

    • Port-side intake fan module with burgundy coloring (NXA-FAN-35CFM-PI)

      Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (1)

      Note

      Table 1. Fan Speeds for This Switch

      Port-Side Intake

      Fan Speed %

      Port-Side Exhaust

      Fan Speed %

      Typical/Minimum

      50%

      70%

      Maximum

      100%

      100%

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2)

    Note

    This switch runs with +1 redundancy mode, so that if one fan fails, the switch can sustain operation. But if a 2nd fan fails, this switch is not designed to sustain operation. Hence before waiting for major threshold temperature to be hit, the switch will power down due to Powered-down due to fan policy trigger.

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (3)

    Note

    Each fan module has two rotors. The switch can function normally if one rotor inside the any one fan module fails. In case of more than one rotor failure, the switch will issue a warning and power down in 2 minute.

  • Power supply modules (two—One for operations and one for redundancy [1+1]) with the following choices:

    • 650-W port-side exhaust AC power supply with blue coloring (NXA-PAC-650W-PE)

    • 650-W port-side intake AC power supply with burgundy coloring (NXA-PAC-650W-PI)

    • 1200-W HVAC/HVDC power supply with dual-direction airflow white coloring (N9K-PUV-1200W)

    • 930-W port-side exhaust DC power supply with blue coloring (NXA-PDC-930W-PE)

    • 930-W port-side intake DC power supply with burgundy coloring (NXA-PDC-930W-PI)

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (4)

    Note

    All fan modules and power supplies must use the same airflow direction.

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (5)

    Note

    This switch may present access issues if installed between switches with greater chassis depth. Please consider this before installation.

Deployment Scheme for SFP-10G-T-X Transceivers

The following figure shows the maximum configuration density of SFP-10G-T-X SFP+ transceivers for this switch.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (6)
Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (7)

Active Port deploying the SFP+ 10GBASE-T transceiver, with max power consumption up to 2.5W.

Once configured with “media-type 10g-tx” in NX-OS or “Link Level Policy -> Physical Media Type -> SFP 10G TX” in ACI, these ports can deploy SFP-10G-T-X. Without such configuration, they behave like normal ports.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (8)

Port Shutdown or Active with Passive Copper Cables only (Max. power consumption up to 0.1W).

Once 10g-tx is configured on yellow ports, ports to the left, right, top and bottom of the yellow port are referenced as blue ports. These adjacent ports will then support only low power Passive Copper DAC cable, or these can be left empty to conserve power. If 10g-tx configuration is removed from adjacent yellow ports, the blue ports will revert to behaving like normal ports.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (9)

Active Port deploying any Cisco 1/10/25G optics (SFP, SFP+, SFP28) EXCLUDING SFP+ 10GBASE-T, with max power consumption up to 1.5W. These ports are not part of any scheme and can deploy all regular Cisco optics and behave like normal ports.

The following figure shows the switch features on the port side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (10)

1

1PPS and 10MHz SMB ports

4

48 100M/1/10/25-Gigabit Ethernet SFP28 ports

2

GPS/GNSS antenna connector

5

6 10/25/40/50/100-Gigabit QSFP28 ports

3

LEDs

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (11)

Note

Time of Day, and PTP GM is not supported

To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver Modules Compatibility Information document.

The following figure shows the switch features on the power supply side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (12)

1

Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (left) and 2 (right)

4

Management port (RJ45)

2

Fan modules (4) with slots numbered from 1 (left) to 4 (right)

5

USB port

3

Console port

6

ToD port

Table 2. ToD/1PPS RS422 Interface-RJ-45 Pinout

Pin

Signal_name

Description

1

NC

No Connect

2

NC

No Connect

3

1PPS_N

1PPS RS422

4

GND

-

5

GND

-

6

1PPS_P

1PPS RS422

7

TOD_N

Time of Day (ToD) RS422

8

TOD_P

Time of Day (ToD) RS422

The following figure shows the side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (13)

1

Screw holes for mounting brackets

3

Grounding pad

Depending on whether you plan to position the ports in a hot or cold aisle, you can order the fan and power supply modules with port-side intake or port-side exhaust airflow. For port-side intake airflow, the fan and power supplies have burgundy coloring. For port-side exhaust airflow, the fan and power supplies have blue coloring.

The fan and power supply modules are field replaceable. You can replace one fan module or one power supply module during operations so long as the other modules are installed and operating. If you have only one power supply installed, you can install the replacement power supply in the open slot before removing the original power supply.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (14)

Note

All fan and power supply modules must have the same direction of airflow. Otherwise, the switch can overheat and shut down.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (15)

Caution

If the switch has port-side intake airflow (burgundy coloring for fan modules), you must locate the ports in the cold aisle. If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2024)

FAQs

What is Nexus ACI mode? ›

ACI mode refers to running the Cisco Nexus 9k switches within the Application Centric Infrastructure architecture, which provides a policy-based, automated approach to network management.

How do I change my Nexus 9000 from ACI mode to NX OS? ›

Converting Back to Cisco NX-OS
  1. Reload the switch.
  2. Enter a break sequence (Ctrl-C or Ctrl-]) during the initial boot sequence to access the loader> prompt.
  3. Configure the boot process to stop at the switch(boot)# prompt.
  4. Boot the active supervisor module with the Cisco NX-OS image.
May 9, 2024

What is Cisco Nexus 93180? ›

The Cisco Nexus 93180YC-FX3 Switch (Figure 1) is a 1RU switch that supports 3.6 Tbps of bandwidth and 1.2 Bpps. The 48 downlink ports on the 93180YC-FX3 are capable of supporting 1-, 10-, or 25-Gbps Ethernet, offering deployment flexibility and investment protection.

What is Cisco Nexus 9000 Series? ›

Cisco Nexus 9000 Series Switches Explained

Built on Cisco silicon, the Cisco Nexus 9000 Series delivers industry-leading data center performance from the inside out.

What is the difference between ACI and switch? ›

Cisco Nexus switches are traditional switches that provide high-speed connectivity and advanced features, while Cisco ACI switches are optimized for use with Cisco's ACI framework and provide policy-based automation and centralized management.

What is the purpose of Nexus switch? ›

The Cisco Nexus Switch product line provides a series of solutions that attempt to make it easier to connect and manage disparate data center resources with software-defined networking (SDN).

What OS does Cisco Nexus use? ›

Cisco NX-OS
DeveloperCisco Systems
OS familyUnix-like
Working stateCurrent
Source modelClosed source
Latest release10.4
1 more row

What are two modes of operation in which Nexus 9000 series switches can be configured? ›

The Nexus 9000 can be used in NXOS mode for traditional 3-tier architectures, Spine-Leaf (CLOS) architectures, or Generation 1 SDN solutions such as OpenFlow. In ACI mode the Nexus 9000 offers the industry's leading architecture for the next generation of data center networking.

How do I connect my Cisco Nexus switch? ›

You can connect to the switch using a terminal plugged into the console port. You can also connect to the switch with Telnet or SSH. The switch supports up to eight simultaneous Telnet and SSH connections. To connect with Telnet or SSH, you need to know the hostname or IP address of the switch.

What is difference between Cisco switch and Nexus switch? ›

Cisco catalyst switches are mainly designed for distro/core layers in campus network vs the Nexus is mainly for data centers. Nexus series switches can support Ethernet, Fiber Channel and FCOE all in the same chassis but the catalyst don't. The catalyst switches support only Ethernet.

What is the port speed of Nexus 93180? ›

The Cisco Nexus 93180LC-EX Switch is the industry's first 50-Gbps-capable 1RU switch that supports 3.6 Tbps of bandwidth and over 2.6 bpps across up to 32 fixed 40- and 50-Gbps QSFP+ ports or up to 18 fixed 100-Gbps ports (Figure 3). The switch can support up to 72 10-Gbps ports using breakout cables.

What is the throughput of a Cisco 93180YC FX3? ›

The Cisco Nexus 93180YC-FX3 Switch is a 1RU switch that supports 3.6 Tbps of bandwidth and 1.2 bpps.

Do Nexus switches have PoE? ›

PoE works on the same network cable that carries network traffic data. The Nexus 9000 platform switches act as the PSE devices to supply power to any device which may require it.

What is Cisco Nexus ACI? ›

Cisco Application Centric Infrastructure (ACI) is a software-defined networking (SDN) solution designed for data centers. Cisco ACI allows network infrastructure to be defined based upon network policies – simplifying, optimizing, and accelerating the application deployment lifecycle.

Is Nexus a router? ›

Cisco Nexus routers are a series of high-performance, modular switches designed for data center environments. These routers provide a scalable and flexible solution for handling the demanding requirements of modern data centers, including high bandwidth, low latency, and high availability.

What does Cisco ACI mean? ›

Cisco Application Centric Infrastructure (ACI) is a software-defined networking (SDN) solution designed for data centers. Cisco ACI allows network infrastructure to be defined based upon network policies – simplifying, optimizing, and accelerating the application deployment lifecycle. Schedule a Demo Watch Webinar.

What is APIC in Nexus? ›

Cisco Application Policy Infrastructure Controller (APIC)

What is an ACI leaf switch? ›

It serves as an intermediary device between endpoints and the spine switches in the data center network fabric. The leaf switches are responsible for connecting servers, storage, and other network devices to the ACI fabric, providing the necessary network connectivity for applications and workloads.

What is ACI virtual edge? ›

Cisco Application Centric Infrastructure Virtual Edge

Virtual Edge, the next generation application virtual switch (AVS), is hypervisor agnostic and handles switching and policy enforcement for the Cisco Application Centric Infrastructure (ACI).

References

Top Articles
Latest Posts
Article information

Author: Dr. Pierre Goyette

Last Updated:

Views: 5823

Rating: 5 / 5 (50 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Dr. Pierre Goyette

Birthday: 1998-01-29

Address: Apt. 611 3357 Yong Plain, West Audra, IL 70053

Phone: +5819954278378

Job: Construction Director

Hobby: Embroidery, Creative writing, Shopping, Driving, Stand-up comedy, Coffee roasting, Scrapbooking

Introduction: My name is Dr. Pierre Goyette, I am a enchanting, powerful, jolly, rich, graceful, colorful, zany person who loves writing and wants to share my knowledge and understanding with you.